Speaker
Mr
ali mohammad poursaleh
(aeoi)
Description
In this paper the different geometries for coaxial cavity of Rhodotron accelerator has been investigated. This cavity resonance in TEM mode, the frequency is 107MHz to state that even small changes in the dimensions will be effect on basic parameters such as the accelerator resonant frequency and power losses, that Using computational relations and the results of simulations by CST software is studied. The main goal of this research is to optimize the geometry of the coaxial cavity with the best parameters to use for Rhodotron accelerator. The results of computation, simulation and experimental show good agreement.
چکیده به فارسی
در اين مقاله هندسه هاي مختلفي از كاواك كواكسيال جهت شتاب دهنده رودترون بررسي وشبيه سازي گرديده است.اين كاواك در مد TEMو با فركانس 107MHzبه حالت تشديد در مي آيد كه حتي تغييرات كوچك ابعادي آن تاثيرات زيادي بر پارامترهاي اساسي در طراحي شتاب دهنده از قبيل فركانس تشديد و توان تلفاتي خواهد داشت , كه با استفاده از روابط محاسباتي و نتايج حاصل از شبيه سازي بوسيله نرم افزارCST مورد بررسي قرار گرفته است. هدف اصلي اين تحقيق دستيابي به هندسه بهينه كاواك كواكسيال با بهترين پارامترها جهت استفاده در شتاب دهنده رودترون مي باشد. نتاج حاصل ازمحاسبات ، شبيه سازي و مشاهدات تجربي تطابق خوبي را نشان مي دهد
عنوان مقاله به فارسی | مطالعات ابعادی و شبيه سازي كاواك شتاب دهنده رودترون جهت دستیابی به هندسه بهینه |
---|
Author
Mr
ali mohammad poursaleh
(aeoi)
Co-authors
Dr
hossein khalafi
(aeoi)
Dr
iraj jabbari
(esfahan univesity)
Peer reviewing
Paper
Paper files: