Speaker
Mr
Sasan Ahmadian
(IPM)
Description
In this article, after overview of design and construction procedure of traveling wave accelerator tube with 9 cavities, its measurements and tuning method and results was reported. Results of cold measurements of electromagnetic characteristics and longitudinal electric field profile along symmetric axes and their comparison with simulation results represented the accuracy of measurement set up and effectiveness of measurements and calculations. Study of environmental conditions on measurements, their correction and variation of electric field profile and number of modes before and after tuning are important aspects of this paper. Also, study of maximum possible values for variation of frequency of cells up to nominal one is another major result of this article. The results of this paper will be used for final measurements and tuning of main accelerator tubes of IPM linac project.
چکیده به فارسی
در این مقاله، پس از مرور نحوه طراحی و ساخت یک تیوب شتابدهی موج رونده در باند s با تعداد 9 کاواک، اندازه¬گیری سرد و تنظیم فرکانسی آن گزارش شده است. نتایج اندازه گیری فرکانس و پروفایل میدان الکتریکی، قبل و بعد از تنظیم فرکانسی و مقایسه آن با نتایج شبیه سازی نشان میدهد که سیستم و روش اندازه گیری صحیح است. بررسی اثر شرایط محیطی بر اندازه گیری ها و نحوه جبران آن ها، چگونگی تغییر پروفایل میدان و تعداد مدها قبل و بعد از تنظیم و نیز میزان تغییر فرکانس ناشی از تغییر شکل دیواره کاواک از دستاوردهای این پژوهش است. از نتایج بدست آمده در این مقاله برای اندازه گیری و تنظیم تیوب های اصلی شتابدهنده خطی پژوهشگاه دانش های بنیادی استفاده خواهد شد.
عنوان مقاله به فارسی | اندازه گیری سرد نمونه کوچک تیوب شتابدهنده خطی الکترون باند s و تنظیم فرکانسی آن |
---|
Author
Mr
Sasan Ahmadian
(IPM)
Peer reviewing
Paper
Paper files: